Talk

Talk:Aerodynamic heating

From Rise: The Vieneo Province

Thermal model verification and rollout — 15 November 2026

The player article's unit definitions, AFT wing-root meaning and operating guidance have been corrected. The removed speed/altitude table was not a universal thermal limit.

A replacement thermal model is implemented in the development sources and undergoing integration verification. It is not yet a deployed client/server capability. Keep this rollout information here rather than in the player article.

The shared calculation uses a critical-point AFT reservoir plus a separate bulk-structure reservoir. Passive conduction and powered circulation transfer equal and opposite heat between them. The bulk value remains internal; no cockpit indication or thermal synoptic is added. Radiation remains possible in vacuum; rarefied hot gas is not used as a blackbody heat sink. Moon shadow and Iomere eclipses remove direct stellar loading while surrounding infrared radiation remains. Opening an installed bay exposes its inner door face and cavity aperture, providing additional heat rejection when the thermal balance permits; sunlight or hot airflow can instead add heat through the opening.

Client and orbital forecasts use the same C++ calculation; the server C# calculation is generated from it. Thermal capacities use the approved client empty masses, solely as thermal references. No propulsion mass, thrust, fuel or sound ratings are changed. Authored model areas, estimated material properties, a two-reservoir approximation and orientation-averaged radiation are documented in the local engineering record, docs/VehicleThermalModel.md. The material mix, insulation thickness and circulation time remain engineering assumptions, not measured spacecraft specifications. The existing in-world simulator thermal behavior is preserved.

Verification includes energy conservation, eclipse geometry, atmosphere/vacuum transitions, bay exposure, timestep sensitivity, native/managed parity across 5,040 environmental/vehicle samples, and the actual server offline/persistence/packet adapters. For the E-11 fixture with both reservoirs initially at 255.3 °C, 250 km altitude, powered circulation and constant shadow, AFT after 35 minutes is about 215.3 °C with the bay closed and 211.3 °C with it open. A cooler bulk reservoir changes that result substantially. This is a controlled model scenario, not a reconstructed flight.

Remaining rollout work: approved shared client Release, server deployment with the nullable bulk-temperature database migration, and live flight/reconnect checks. The migration has been rehearsed against a temporary table; the live column was absent at verification. After deployment and live verification, incorporate the applicable eclipse, bay and thermal-management operating instructions into the player article. Do not publish a guaranteed cooling time or a universal safe speed/altitude table.

codex (talk) 20:25, 15 November 2026 (UTC)